Eaton HCP0805-2R2-R: iron powder high-current inductor, 2.2 uH ±20%, 10 A Irms, Isat 14 A, DCR 11.2 mOhm, 7.9 x 7.6 mm.
    • Product Details
    • Download

    Eaton HCP0805-2R2-R Iron Powder Inductor 2.2 uH, Isat 14 A

    HCP0805-2R2-R at a glance: iron powder high-current inductor, 2.2 uH ±20%, 10 A Irms, Isat 14 A (20% rolloff @ +25 °C), DCR 11.2 mOhm, 7.9 x 7.6 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCP0805-2R2-R
    OCL (open circuit inductance)2.2 uH ±20%
    FLL minimum, at Isat1.41 uH
    Irms (DC, 40 °C rise)10 A
    Isat (20% rolloff @ +25 °C)14 A
    DCR typical @ +20 °C11.2 mOhm
    K-factor (Bp-p = K x L x dI)175, Bp-p in Gauss
    Package7.9 x 7.6 mm
    Height5.0 mm
    MountingSurface mount
    Operating temperature-40 °C to +125 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4349

    Mechanical Dimensions & Pad Layout

    HCP0805-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4349: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    How to Read These Ratings

    Iron powder core in a shielded surface-mount body: the material gives a soft saturation curve, so inductance falls gradually with current rather than dropping off a cliff. The part is aimed at VRM and point-of-load stages where the inductor spends its working life part-way up the saturation curve.

    With 11.2 mOhm typical, the I-squared-R loss at the full 10 A rating is about 1.12 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +25 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    The core stores roughly 216 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 175 means the flux swing is about 385 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    Positioning in the Range

    The HCP family is the iron powder, shielded, high-current range for VRM and point-of-load work. It covers modest inductance values at high DC bias, with the soft saturation curve that iron powder is chosen for.

    In the HCP0805 line-up this part is number 5 of 5 by inductance, between 0.4 uH and 2.2 uH.

    Compared with its neighbours in the table, HCP0805-1R5-R trades 0 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 7.9 x 7.6 mm body at 5.0 mm.
    • Typical applications: multi-phase regulators; voltage regulator modules (vrms); distributed power systems dc-dc converters; desktop and server vrms and evrds; point-of-load (pol) modules; field programmable gate array (fpga) dc-dc converters.
    • Iron powder has a soft saturation curve but a lower permeability than ferrite, so the turns count – and therefore the DCR – is higher for the same inductance.

    Sizing and Layout Notes

    Copper resistance rises with temperature, so at the +125 °C limit the maximum DCR of 11.2 mOhm becomes roughly 15.8 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: at high DC bias the inductance is well below OCL. Use the inductance-versus-current curve for the ripple calculation, not the headline value.

    • Verify the footprint against the recommended pad layout.
    • Account for the lower permeability of iron powder in the turns count and DCR.
    • Account for the lower permeability of iron powder in the turns count and DCR.

    Frequently Asked Questions

    What does the K-factor tell me?
    It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.

    What does the K-factor tell me?
    It converts inductance and ripple current into flux swing: K times L times delta-I gives Bp-p. That amplitude is what the core-loss graph is plotted against.

    What core loss should I expect?
    Read the core-loss curve at the flux amplitude implied by the K-factor and the ripple, at the switching frequency. Core loss is quoted per unit volume, so compare curves rather than single numbers.