Eaton HCPT1309-1R0-R THT Inductor 0.96 uH, Isat 30.9 A
Eaton HCPT1309-1R0-R THT Inductor 0.96 uH, Isat 30.9 A

Eaton HCPT1309-1R0-R THT Inductor 0.96 uH, Isat 30.9 A

Share
Eaton HCPT1309-1R0-R: through-hole high-current inductor, 0.96 uH ±20%, 19.4 A Irms, Isat 30.9 A, DCR 1.9 mOhm, 13.2 x 13.2 mm.
    • Product Details
    • Download

    Eaton HCPT1309-1R0-R THT Inductor 0.96 uH, Isat 30.9 A

    HCPT1309-1R0-R at a glance: through-hole high-current inductor, 0.96 uH ±20%, 19.4 A Irms, Isat 30.9 A (20% rolloff @ +20 °C), DCR 1.9 mOhm, 13.2 x 13.2 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCPT1309-1R0-R
    OCL (open circuit inductance)0.96 uH ±20%
    Irms (DC, 40 °C rise)19.4 A
    Isat (20% rolloff @ +20 °C)30.9 A
    Isat2 (30% rolloff @ +20 °C)40 A
    DCR typical @ +20 °C1.9 mOhm
    K-factor (Bp-p = K x L x dI)66, Bp-p in Gauss
    Package13.2 x 13.2 mm
    Height9.0 mm
    MountingThrough-hole, vertical
    Operating temperature-40 °C to +105 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4138

    Mechanical Drawing

    HCPT1309-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4138: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Vertical through-hole mounting puts the core axis perpendicular to the board, so the part occupies less board area than a flat inductor of the same volume. That is the reason this family exists: current density per square millimetre, at the cost of a taller profile.

    With 1.9 mOhm typical, the I-squared-R loss at the full 19.4 A rating is about 0.715 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    The saturation rating reads 20% rolloff @ +20 °C. Treat it as the edge of the linear region: below it the inductance is within tolerance, above it the value droops. For a current-mode converter that means the peak current at the worst-case load step is what must fit under this number.

    Stored energy at Isat is about 458 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    With K = 66, a peak-to-peak ripple of one amp produces roughly 63.4 Gauss of flux swing. Read the core-loss graph at that amplitude and at the switching frequency to get the core contribution to the total loss.

    The second saturation column, 40 A at 30% rolloff @ +20 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HCPT family is the through-hole, vertical-mount high-current range. It exists for boards that need maximum current per square millimetre and are assembled by wave or selective soldering rather than reflow.

    The HCPT1309 family spans 0.2 uH to 3.31 uH; this row sits at position 3 of 6.

    One step down the table, HCPT1309-R47-R, sits at 0.49 uH with 34 A and 0.624 mOhm – the lower inductance buys about 20.3 A of extra current in the same body.

    • Core material: iron powder core, 13.2 x 13.2 mm body at 9.0 mm.
    • Typical applications: next generation processors; high current dc-dc converters; vrm, multi-phase buck regulator; desktop computers; video game power.
    • Through-hole mounting puts the solder joint in the current path. Check the joint and the plated barrel, not just the lead, against the rated current.

    Design Notes

    Copper resistance rises with temperature, so at the +105 °C limit the maximum DCR of 1.9 mOhm becomes roughly 2.53 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the vertical body blocks airflow across the board. If the enclosure relies on lateral airflow, check the thermal path through the leads and the copper around them.

    • Check the standing height against the enclosure clearance.
    • Verify vertical clearance above the board for the standing body.
    • Confirm the hole size and plating against the lead diameter.

    Frequently Asked Questions

    Does the vertical body affect cooling?
    It blocks lateral airflow, so the thermal path is through the leads and the copper around them. Check the joint temperature, not just the body temperature.

    Does the vertical body affect cooling?
    It blocks lateral airflow, so the thermal path is through the leads and the copper around them. Check the joint temperature, not just the body temperature.

    How is it mounted?
    Vertically, with the core axis perpendicular to the board. Two leads drop into plated through-holes; the body stands clear of the surface.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products