Eaton HCPT1309-2R2-R 2.27 uH Through-Hole Inductor, 12.5 A
Eaton HCPT1309-2R2-R 2.27 uH Through-Hole Inductor, 12.5 A

Eaton HCPT1309-2R2-R 2.27 uH Through-Hole Inductor, 12.5 A

Share
Eaton HCPT1309-2R2-R: through-hole high-current inductor, 2.27 uH ±20%, 12.5 A Irms, Isat 19.7 A, DCR 4.1 mOhm, 13.2 x 13.2 mm.
    • Product Details
    • Download

    Eaton HCPT1309-2R2-R 2.27 uH Through-Hole Inductor, 12.5 A

    HCPT1309-2R2-R at a glance: through-hole high-current inductor, 2.27 uH ±20%, 12.5 A Irms, Isat 19.7 A (20% rolloff @ +20 °C), DCR 4.1 mOhm, 13.2 x 13.2 mm.

    Ratings at a Glance

    ParameterValue
    Orderable part numberHCPT1309-2R2-R
    OCL (open circuit inductance)2.27 uH ±20%
    Irms (DC, 40 °C rise)12.5 A
    Isat (20% rolloff @ +20 °C)19.7 A
    Isat2 (30% rolloff @ +20 °C)25 A
    DCR typical @ +20 °C4.1 mOhm
    K-factor (Bp-p = K x L x dI)42, Bp-p in Gauss
    Package13.2 x 13.2 mm
    Height9.0 mm
    MountingThrough-hole, vertical
    Operating temperature-40 °C to +105 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4138

    Mechanical Dimensions & Pad Layout

    HCPT1309-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4138: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    The Figures Explained

    Vertical through-hole mounting puts the core axis perpendicular to the board, so the part occupies less board area than a flat inductor of the same volume. That is the reason this family exists: current density per square millimetre, at the cost of a taller profile.

    With 4.1 mOhm typical, the I-squared-R loss at the full 12.5 A rating is about 0.641 W. Compare that against the converter output power before deciding whether the part needs airflow or a copper pour under it.

    Saturation is quoted as 20% rolloff @ +20 °C. At that point the inductance has fallen to the stated fraction of its nominal value – the part is not damaged there, it simply stops behaving like the inductance on the label. Design the peak current to stay inside that boundary with margin for tolerance.

    The core stores roughly 440 uJ at the saturation point – a useful figure when sizing the output capacitance that has to absorb the same transient.

    K-factor 42 means the flux swing is about 95.3 Gauss per amp of ripple. Core loss scales with the flux amplitude and the frequency, so this is the number to carry into the loss calculation rather than the inductance alone.

    The second saturation column, 25 A at 30% rolloff @ +20 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Series Positioning

    The HCPT family is the through-hole, vertical-mount high-current range. It exists for boards that need maximum current per square millimetre and are assembled by wave or selective soldering rather than reflow.

    Of the 6 values listed for HCPT1309, this is the 5th, in a family covering 0.2 uH to 3.31 uH.

    Compared with its neighbours in the table, HCPT1309-3R3-R trades 2.3 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 13.2 x 13.2 mm body at 9.0 mm.
    • Typical applications: next generation processors; high current dc-dc converters; vrm, multi-phase buck regulator; desktop computers; video game power.
    • Through-hole mounting puts the solder joint in the current path. Check the joint and the plated barrel, not just the lead, against the rated current.

    Putting It to Work

    Copper resistance rises with temperature, so at the +105 °C limit the maximum DCR of 4.1 mOhm becomes roughly 5.47 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the vertical body blocks airflow across the board. If the enclosure relies on lateral airflow, check the thermal path through the leads and the copper around them.

    • Confirm the hole size and plating against the lead diameter.
    • Verify vertical clearance above the board for the standing body.
    • Check the standing height against the enclosure clearance.

    Frequently Asked Questions

    What are the two saturation figures?
    The same peak current measured at two rolloff criteria – 20 % and 30 % of inductance. They are design boundaries, not damage limits.

    What are the two saturation figures?
    The same peak current measured at two rolloff criteria – 20 % and 30 % of inductance. They are design boundaries, not damage limits.

    Can the part be placed by machine?
    Vertical through-hole parts are usually placed by radial insertion equipment or by hand, then wave or selectively soldered. Check the line’s capability before specifying it.