Eaton HCPT1309-R47-R 0.49 uH Vertical Power Inductor
Eaton HCPT1309-R47-R 0.49 uH Vertical Power Inductor

Eaton HCPT1309-R47-R 0.49 uH Vertical Power Inductor

Share
Eaton HCPT1309-R47-R: through-hole high-current inductor, 0.49 uH ±20%, 34 A Irms, Isat 43.3 A, DCR 0.624 mOhm, 13.2 x 13.2 mm.
    • Product Details
    • Download

    Eaton HCPT1309-R47-R 0.49 uH Vertical Power Inductor

    HCPT1309-R47-R at a glance: through-hole high-current inductor, 0.49 uH ±20%, 34 A Irms, Isat 43.3 A (20% rolloff @ +20 °C), DCR 0.624 mOhm, 13.2 x 13.2 mm.

    Specification Table

    ParameterValue
    Orderable part numberHCPT1309-R47-R
    OCL (open circuit inductance)0.49 uH ±20%
    Irms (DC, 40 °C rise)34 A
    Isat (20% rolloff @ +20 °C)43.3 A
    Isat2 (30% rolloff @ +20 °C)55 A
    DCR typical @ +20 °C0.624 mOhm
    K-factor (Bp-p = K x L x dI)92.4, Bp-p in Gauss
    Package13.2 x 13.2 mm
    Height9.0 mm
    MountingThrough-hole, vertical
    Operating temperature-40 °C to +105 °C (ambient plus self-heating)
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4138

    Mechanical Dimensions & Pad Layout

    HCPT1309-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4138: outline with
    rated mm dimensions, recommended pad layout and winding schematic. Tolerances are stated on
    the drawing itself.

    What the Numbers Mean

    A through-hole power inductor with a vertical mounting style: the body stands on the board and the leads drop into plated holes, which is how this family gets a large core volume and a thick winding into a small board area. Used where the current is high enough that a surface-mount termination is the weak point.

    The DCR figure of 0.624 mOhm is what sets the efficiency: at 34 A the winding drops about 0.021 mV and dissipates 0.721 W. On a low-voltage rail that drop is a measurable fraction of the output, so the DCR column deserves as much attention as the inductance.

    The Isat column is 20% rolloff @ +20 °C. Note what it does and does not mean: it is a defined rolloff point, not a destruction limit. Above it the inductance continues to fall, which is why the transient peak current should be checked against the curve, not just against the number.

    Stored energy at Isat is about 459 uJ, which is the energy the inductor hands to the load during a transient before the control loop reacts.

    The K-factor of 92.4 converts inductance and ripple into flux swing: each amp of peak-to-peak ripple moves the core through about 45.3 Gauss of Bp-p, the figure the core-loss curve is plotted against.

    The second saturation column, 55 A at 30% rolloff @ +20 °C, is the same core taken further into rolloff. The ratio between the two columns is a direct measure of how soft the curve is: a part with a wide gap between them loses inductance slowly and tolerates a larger transient peak.

    Positioning in the Range

    The HCPT family is the through-hole, vertical-mount high-current range. It exists for boards that need maximum current per square millimetre and are assembled by wave or selective soldering rather than reflow.

    The HCPT1309 family spans 0.2 uH to 3.31 uH; this row sits at position 2 of 6.

    Compared with its neighbours in the table, HCPT1309-1R0-R trades 23.7 A of rated current for the next inductance step, which is the usual compromise in this family.

    • Core material: iron powder core, 13.2 x 13.2 mm body at 9.0 mm.
    • Typical applications: next generation processors; high current dc-dc converters; vrm, multi-phase buck regulator; desktop computers; video game power.
    • Through-hole mounting puts the solder joint in the current path. Check the joint and the plated barrel, not just the lead, against the rated current.

    Sizing It Into a Design

    Copper resistance rises with temperature, so at the +105 °C limit the maximum DCR of 0.624 mOhm becomes roughly 0.832 mOhm. That is the figure to put into a hot-enclosure loss calculation; the +20 °C column is a bench number.

    Design note: the vertical body blocks airflow across the board. If the enclosure relies on lateral airflow, check the thermal path through the leads and the copper around them.

    • Check the standing height against the enclosure clearance.
    • Check the solder joint and plated barrel against the rated current.
    • Verify vertical clearance above the board for the standing body.

    Frequently Asked Questions

    What are the two saturation figures?
    The same peak current measured at two rolloff criteria – 20 % and 30 % of inductance. They are design boundaries, not damage limits.

    Does the vertical body affect cooling?
    It blocks lateral airflow, so the thermal path is through the leads and the copper around them. Check the joint temperature, not just the body temperature.

    Why through-hole for a power inductor?
    The leads carry current and heat into the board, and the body can be larger because it is not constrained by reflow standoff. On a wave-soldered board that gives more current per unit of board area.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products