Eaton HCV1206-R42-R 0.42 uH Inductor, Isat 42 A
Eaton HCV1206-R42-R 0.42 uH Inductor, Isat 42 A

Eaton HCV1206-R42-R 0.42 uH Inductor, Isat 42 A

Share
HCV1206-R42-R: high-current power inductor, 0.42 uH, 16 A, Isat 42 A, DCR 3.15 mOhm.
    • Product Details
    • Download

    Eaton HCV1206-R42-R 0.42 uH Inductor, Isat 42 A

    HCV1206-R42-R at a glance: high-current power inductor, 0.42 uH, 16 A, Isat 42 A, DCR 3.15 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberHCV1206-R42-R
    Inductance0.42 nH ±20%
    DCR maximum @ +25 °C3.15 mOhm
    Irms (DC, 40 °C rise)16 A
    Isat42 A
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10354

    Mechanical Dimensions & Pad Layout

    HCV1206-R42-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10354: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    What the Numbers Mean

    A shielded power inductor with a soft saturation curve: as the current rises the inductance droops rather than collapsing, so the regulator keeps control through a load transient. The molded body contains the field, which is why these parts can sit side by side on a multiphase rail without coupling into each other.

    At 16 A the winding dissipates about 0.806 W in copper, using the 3.15 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 42 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HCV1206 family this is value 1 of 7, in a range that runs from 0.42 to 3 uH.

    Positioning in the Range

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: compatible with picor® cool-power® zvs buckand buck-boost regulator families (picor part number series pi37xx and pi35xx).
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.