Eaton HFW1V2818H220K 22.0 uH Inductor, Isat 28 A
Eaton HFW1V2818H220K 22.0 uH Inductor, Isat 28 A

Eaton HFW1V2818H220K 22.0 uH Inductor, Isat 28 A

Share
HFW1V2818H220K: high-current power inductor, 22.0 uH, 11.5 A, Isat 28 A, DCR 14 mOhm.
    • Product Details
    • Download

    Eaton HFW1V2818H220K 22.0 uH Inductor, Isat 28 A

    HFW1V2818H220K at a glance: high-current power inductor, 22.0 uH, 11.5 A, Isat 28 A, DCR 14 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberHFW1V2818H220K
    Inductance22.0 uH ±20%
    DCR maximum @ +25 °C14 mOhm
    Irms (DC, 40 °C rise)11.5 A
    Isat28 A
    SRF typical2.86 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1330

    Mechanical Drawing

    HFW1V2818H220K mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data ELX1330: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    The Figures Explained

    This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.

    At 11.5 A the winding dissipates about 1.85 W in copper, using the 14 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 28 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HFW1V2818H220K family this is value 1 of 1, in a range that runs from 22 to 22 uH.

    What This Family Is For

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: computing (pol/vrms); distributed power architectures; servers and workstations; lan / wan applications; game consoles.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products