Eaton HPAL1V0630-R22-R 0.22 uH Inductor, Isat 34 A
Eaton HPAL1V0630-R22-R 0.22 uH Inductor, Isat 34 A

Eaton HPAL1V0630-R22-R 0.22 uH Inductor, Isat 34 A

Share
HPAL1V0630-R22-R: high-current power inductor, 0.22 uH, 24 A, Isat 34 A, DCR 2.1 mOhm.
    • Product Details
    • Download

    Eaton HPAL1V0630-R22-R 0.22 uH Inductor, Isat 34 A

    HPAL1V0630-R22-R at a glance: high-current power inductor, 0.22 uH, 24 A, Isat 34 A, DCR 2.1 mOhm.

    Electrical Specifications

    ParameterValue
    Orderable part numberHPAL1V0630-R22-R
    Inductance0.22 nH ±20%
    DCR maximum @ +25 °C2.1 mOhm
    Irms (DC, 40 °C rise)24 A
    Isat34 A
    FLL minimum (at Isat)0.124 uH
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 11080

    Dimensions and Pad Layout

    Outline drawing and pad layout are on page 2 of Eaton Technical Data 11080; the package column above gives the body size in millimetres.

    What the Numbers Mean

    A shielded power inductor with a soft saturation curve: as the current rises the inductance droops rather than collapsing, so the regulator keeps control through a load transient. The molded body contains the field, which is why these parts can sit side by side on a multiphase rail without coupling into each other.

    At 24 A the winding dissipates about 1.21 W in copper, using the 2.1 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 34 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HPAL1V0630 family this is value 2 of 16, in a range that runs from 0.15 to 10 uH.

    What This Family Is For

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules (pol); desktop and server vrms and evrds; base station equipment.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.