| Parameter | Value |
|---|---|
| Orderable part number | HPAL1V0630-R68-R |
| Inductance | 0.68 nH ±20% |
| DCR maximum @ +25 °C | 4.8 mOhm |
| Irms (DC, 40 °C rise) | 16 A |
| Isat | 17 A |
| FLL minimum (at Isat) | 0.381 uH |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11080 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 11080; the package column above gives the body size in millimetres.
Power inductors in this family are chosen on three numbers: inductance for the ripple, saturation current for the transient, and DCR for the loss. The data sheet gives all three against a defined test condition, which is what makes the row comparable with parts from other vendors.
At 16 A the winding dissipates about 1.23 W in copper, using the 4.8 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 17 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the HPAL1V0630 family this is value 6 of 16, in a range that runs from 0.15 to 10 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
Is the part shielded?
The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.
Why are there two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.
Why are there two DCR columns?
Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.