| Parameter | Value |
|---|---|
| Orderable part number | HPAL1V1040-150-R |
| Inductance | 15.0 uH ±20% |
| DCR maximum @ +25 °C | 41 mOhm |
| Irms (DC, 40 °C rise) | 5.2 A |
| Isat | 7 A |
| FLL minimum (at Isat) | 8.4 uH |
| SRF typical | 9.8 MHz |
| K-factor | 89 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11083 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 11083; the package column above gives the body size in millimetres.
The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.
At 5.2 A the winding dissipates about 1.11 W in copper, using the 41 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.
Saturation is reached at 7 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the HPAL1V1040 family this is value 16 of 19, in a range that runs from 0.22 to 47 uH.
The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.
How much inductance is left at rated current?
The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.
How much inductance is left at rated current?
The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.
What is the difference between Irms and Isat?
Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.