Eaton HPAL1V1040-1R0-R 1.0 uH High-Current Inductor
Eaton HPAL1V1040-1R0-R 1.0 uH High-Current Inductor

Eaton HPAL1V1040-1R0-R 1.0 uH High-Current Inductor

Share
HPAL1V1040-1R0-R: high-current power inductor, 1.0 uH, 19 A, Isat 28 A, DCR 2.8 mOhm.
    • Product Details
    • Download

    Eaton HPAL1V1040-1R0-R 1.0 uH High-Current Inductor

    HPAL1V1040-1R0-R at a glance: high-current power inductor, 1.0 uH, 19 A, Isat 28 A, DCR 2.8 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberHPAL1V1040-1R0-R
    Inductance1.0 uH ±20%
    DCR maximum @ +25 °C2.8 mOhm
    Irms (DC, 40 °C rise)19 A
    Isat28 A
    FLL minimum (at Isat)0.56 uH
    SRF typical44 MHz
    K-factor293
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 11083

    Outline Drawing

    Outline drawing and pad layout are on page 2 of Eaton Technical Data 11083; the package column above gives the body size in millimetres.

    What the Numbers Mean

    A shielded power inductor with a soft saturation curve: as the current rises the inductance droops rather than collapsing, so the regulator keeps control through a load transient. The molded body contains the field, which is why these parts can sit side by side on a multiphase rail without coupling into each other.

    At 19 A the winding dissipates about 1.01 W in copper, using the 2.8 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 28 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the HPAL1V1040 family this is value 8 of 19, in a range that runs from 0.22 to 47 uH.

    Positioning in the Range

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: voltage regulator module (vrm); multi-phase regulators; point-of-load modules (pol); desktop and server vrms and evrds; base station equipment.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products