| Parameter | Value |
|---|---|
| Orderable part number | LAN2VSOPD48351C2 |
| Ports | Dual |
| Pins | 48 |
| Leakage inductance | 10.8 uH |
| DCR maximum | 600 mOhm |
| Inter-winding capacitance | 35 pF |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | -40 C to +85 C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1376 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1376; the package line above gives the body size where
the data sheet states it.
A LAN transformer provides the isolation and the common mode rejection between the cable and the PHY. The turns ratio is fixed at 1CT:1CT for Ethernet, so the design work is in the inductance, the leakage and the inter-winding capacitance – those three set insertion loss, return loss and crosstalk.
Within the LAN2VSOPD48351C2 family this is item 1 of 1 in the Eaton catalogue.
The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.
Why is inductance quoted at a DC bias?
The PHY or the PoE feed pushes a DC current through the winding, and the core saturates a little. The bias condition in the table is the one the number applies to; without it the figure is meaningless.
What does 1CT:1CT mean?
Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.
Does the part include the common mode choke?
Only where the part number or the description says so. Many designs use a separate choke; the PoE variants with a CMC in the same package are marked as such.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd