Eaton LAN5VSOPS24121C3 LAN Magnetics, 24 Pins
Eaton LAN5VSOPS24121C3 LAN Magnetics, 24 Pins

Eaton LAN5VSOPS24121C3 LAN Magnetics, 24 Pins

Share
LAN5VSOPS24121C3: LAN transformer, single port.
    • Product Details
    • Download

    Eaton LAN5VSOPS24121C3 LAN Magnetics, 24 Pins

    LAN5VSOPS24121C3 at a glance: LAN transformer, single port.

    Specification Table

    ParameterValue
    Orderable part numberLAN5VSOPS24121C3
    PortsSingle
    Pins24
    Leakage inductance0.5 uH
    DCR maximum1.4 Ohm
    Inter-winding capacitance35 pF
    PackageSee dimension drawing in the data sheet
    MountingSurface mount
    Operating temperature-40 C to +125 C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data ELX1381

    Outline drawing, winding arrangement and recommended pad layout are on
    page 2 of Eaton Technical Data ELX1381; the package line above gives the body size where
    the data sheet states it.

    What the Numbers Mean

    A LAN transformer provides the isolation and the common mode rejection between the cable and the PHY. The turns ratio is fixed at 1CT:1CT for Ethernet, so the design work is in the inductance, the leakage and the inter-winding capacitance – those three set insertion loss, return loss and crosstalk.

    Within the LAN5VSOPS24121C3 family this is item 1 of 1 in the Eaton catalogue.

    Positioning in the Range

    The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.

    • The magnetics set the return loss and crosstalk floor of the link. A marginal part cannot be fixed in layout.
    • Typical applications: selv/elv equipment; ip telephones; wireless lan access point; iot, remote monitoring; smart tv.
    • Design note: insertion loss and return loss are band specifications. Compare curves at the band edges, not the typical number.

    Frequently Asked Questions

    What does 1CT:1CT mean?
    Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.

    Which port count do I need?
    One transformer per port. The single, dual and quad variants are the same magnetics repeated in one package, which is why the pin count scales with the port count.

    What is CWW?
    Inter-winding capacitance. It is the path that lets common mode noise through the transformer, so lower is better for EMC. It is a construction parameter, not something the layout can fix.