| Parameter | Value |
|---|---|
| Orderable part number | LD2-2R2-HV |
| Inductance | 2.2 uH ±20% |
| DCR maximum @ +25 °C | 20 mOhm |
| Isat | 5 A |
| FLL minimum (at Isat) | 1.41 uH |
| Impulse test voltage | 1100 V |
| Hi-pot test voltage | 1000 V |
| Mounting | Through-hole |
| Operating temperature | -25 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1200 |

Drawing reproduced from Eaton Technical Data ELX1200: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
This is a wound inductor on a drum core with metalized terminations. The value range runs from about a microhenry into the tens of microhenry, which puts it in the region where a multilayer part would need too many turns to be practical.
Saturation is reached at 5 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.
Within the LD2 family this is value 3 of 41, in a range that runs from 1 to 2200 uH.
The drum core family covers about 1 µH to tens of microhenry in axial, radial and surface-mount bodies. It is the value range between the chip inductors and the large toroids.
Is the part shielded?
The drum concentrates flux in the core but the ends are open. Keep sensitive traces away from the axis of the part.
Is the part shielded?
The drum concentrates flux in the core but the ends are open. Keep sensitive traces away from the axis of the part.
Why use a drum core rather than a molded part?
More inductance per unit cost in the mid range, and a wider value selection. The trade is a more open magnetic path and a larger body.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd