| Parameter | Value |
|---|---|
| Orderable part number | LTA1VS16C-351-R |
| Ports | Single |
| Pins | 16 |
| Inductance | 350 uH |
| Leakage inductance | 0.5 uH |
| DCR maximum | 1.2 Ohm |
| Inter-winding capacitance | 35 pF |
| Insertion loss | -1.1 dB @ 0.5-100 MHz |
| Return loss | -18 dB @ 0.5-30 MHz |
| Crosstalk | -30 dB @ 0.5-100 MHz |
| Package | See dimension drawing in the data sheet |
| Mounting | Surface mount |
| Operating temperature | -40 C to +125 C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data ELX1396 |
Outline drawing, winding arrangement and recommended pad layout are on
page 2 of Eaton Technical Data ELX1396; the package line above gives the body size where
the data sheet states it.
This is a toroid-wound LAN transformer on an open header: surface mount, one winding per pair, centre tap brought out. Inductance is quoted with a DC bias condition because the PHY drives a bias current through the winding.
Insertion loss of -1.1 dB @ 0.5-100 MHz is the figure that matters at the band edge; the inductance value only guarantees the low-frequency corner.
Within the LTA1VS16C family this is item 1 of 1 in the Eaton catalogue.
The LAN range covers 100BASE-T through 10GBASE-T, single to quad port, with and without PoE, in open-header SMT packages.
What is CWW?
Inter-winding capacitance. It is the path that lets common mode noise through the transformer, so lower is better for EMC. It is a construction parameter, not something the layout can fix.
What is CWW?
Inter-winding capacitance. It is the path that lets common mode noise through the transformer, so lower is better for EMC. It is a construction parameter, not something the layout can fix.
What does 1CT:1CT mean?
Centre-tapped to centre-tapped, one to one. Ethernet PHYs are designed around this ratio, so a different ratio changes the impedance seen by the PHY and the link will not meet its return loss specification.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd