| Parameter | Value |
|---|---|
| Orderable part number | MCL1608V1-1R5-R |
| Inductance | 1.5 uH |
| DCR maximum @ +25 °C | 350 mOhm |
| Rated current maximum | 120 mA |
| SRF minimum | 60 MHz |
| Test frequency | 1 MHz |
| Test voltage | 50 mV |
| Package | 1.6 x 0.8 mm |
| Size code | 1608 (0603) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10926 |

Drawing reproduced from Eaton Technical Data 10926: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
A multilayer chip inductor is a coil printed in layers of ceramic and metal, fired into a single body. There is no winding to buzz or shift, the inductance is set by the printed pattern, and the part sits on the board like any other 0402 or 0603 component. That construction is why these parts are used wherever the value is small and the quantity is large.
The row reads 1.5 uH with a minimum Q of – at 1 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of – means the part’s loss is about 100 % of its reactance in that band.
Self-resonance is quoted as 60 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 60 MHz is the design headroom.
Within the MCL1608V1 family this is value 19 of 30, in a range that runs from 0.047 to 12 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
How much does the value drift with temperature?
The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd