Eaton MCLA1005V2-5R1-R 5.1 nH Chip Inductor, 8 Q
Eaton MCLA1005V2-5R1-R 5.1 nH Chip Inductor, 8 Q

Eaton MCLA1005V2-5R1-R 5.1 nH Chip Inductor, 8 Q

Share
MCLA1005V2-5R1-R: multilayer chip inductor, 5.1 nH ±0.3nH, Q 8, SRF 4000 MHz, 300 mA, DCR 250 mOhm.
    • Product Details
    • Download

    Eaton MCLA1005V2-5R1-R 5.1 nH Chip Inductor, 8 Q

    MCLA1005V2-5R1-R at a glance: multilayer chip inductor, 5.1 nH ±0.3nH, Q 8, SRF 4000 MHz, 300 mA, DCR 250 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMCLA1005V2-5R1-R
    Inductance5.1 nH ±0.3nH
    Q minimum8
    DCR maximum @ +25 °C250 mOhm
    Rated current maximum300 mA
    SRF minimum4000 MHz
    Test frequency100 MHz
    Test voltage50 mV
    Package1.0 x 0.5 mm
    Size code1005 (0402)
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationAEC-Q200
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10974

    Dimensions and Pad Layout

    MCLA1005V2-5R1-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10974: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    Reading the Data Sheet

    This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.

    The row reads 5.1 nH ±0.3nH with a minimum Q of 8 at 100 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 8 means the part’s loss is about 12.5 % of its reactance in that band.

    Self-resonance is quoted as 4000 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 4000 MHz is the design headroom.

    Within the MCLA1005V2 family this is value 18 of 45, in a range that runs from 0.001 to 0.33 nH.

    Where This Series Fits

    The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.

    • The rated current is a thermal limit for the part in free air, not a saturation limit. At high ambient the current has to be derated.
    • Typical applications: adas; infotainment; wireless communications; wifi, bluetooth, satellite; antennas tuning.
    • Design note: compare SRF against the highest frequency the circuit will see, not just the fundamental.

    Frequently Asked Questions

    What happens above the self-resonant frequency?
    The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.

    Why is the inductance quoted at a test frequency?
    At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.

    What happens above the self-resonant frequency?
    The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.