| Parameter | Value |
|---|---|
| Orderable part number | MCLA1608V1-R082-R |
| Inductance | 0.082 nH ±10 |
| Q minimum | 15 |
| DCR maximum @ +25 °C | 200 mOhm |
| Rated current maximum | 50 mA |
| SRF minimum | 245 MHz |
| Test frequency | 50 MHz |
| Test voltage | 50 mV |
| Package | 1.6 x 0.8 mm |
| Size code | 1608 (0603) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10975 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 10975; the package column above gives the body size in millimetres.
This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.
The row reads 0.082 nH ±10 with a minimum Q of 15 at 50 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 15 means the part’s loss is about 6.67 % of its reactance in that band.
Self-resonance is quoted as 245 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 245 MHz is the design headroom.
Within the MCLA1608V1 family this is value 4 of 24, in a range that runs from 0.047 to 3.9 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
How much does the value drift with temperature?
The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.