| Parameter | Value |
|---|---|
| Orderable part number | MCLA1608V2-221-R |
| Inductance | 220.0 nH ±5% |
| Q minimum | 8 |
| DCR maximum @ +25 °C | 2400 mOhm |
| Rated current maximum | 200 mA |
| SRF minimum | 350 MHz |
| Test frequency | 50 MHz |
| Test voltage | 50 mV |
| Package | 1.6 x 0.8 mm |
| Size code | 1608 (0603) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10976 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 10976; the package column above gives the body size in millimetres.
The inductance here is a few nanohenry, which puts the part in RF and high-speed digital territory: matching networks, filter sections, bias chokes on amplifier supplies, and the small isolation inductors that keep clock harmonics out of connectors. The multilayer body keeps the parasitics predictable, and the Q column tells you how much loss the part adds at the test frequency.
The row reads 220.0 nH ±5% with a minimum Q of 8 at 50 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 8 means the part’s loss is about 12.5 % of its reactance in that band.
Self-resonance is quoted as 350 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 350 MHz is the design headroom.
Within the MCLA1608V2 family this is value 29 of 34, in a range that runs from 0.001 to 0.47 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd