| Parameter | Value |
|---|---|
| Orderable part number | MCLA4532V1-4R7-R |
| Inductance | 4.7 uH ±10 |
| Q minimum | 30 |
| DCR maximum @ +25 °C | 900 mOhm |
| Rated current maximum | 500 mA |
| SRF minimum | 25 MHz |
| Test frequency | 10 MHz |
| Test voltage | 50 mV |
| Package | 4.5 x 3.2 mm |
| Size code | 4532 (1812) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 10980 |
Outline drawing and pad layout are on page 2 of Eaton Technical Data 10980; the package column above gives the body size in millimetres.
This is a surface-mount multilayer inductor: printed coil, sintered body, silver terminations. The value is quoted at a defined test frequency because at these inductances the measurement conditions matter as much as the part.
The row reads 4.7 uH ±10 with a minimum Q of 30 at 10 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 30 means the part’s loss is about 3.33 % of its reactance in that band.
Self-resonance is quoted as 25 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 25 MHz is the design headroom.
Within the MCLA4532V1 family this is value 9 of 14, in a range that runs from 1 to 12 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
How much does the value drift with temperature?
The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.