| Parameter | Value |
|---|---|
| Orderable part number | MCQ1V1608-R180-R |
| Inductance | 0.18 nH ±10 |
| Q minimum | 20 |
| DCR maximum @ +25 °C | 300 mOhm |
| Rated current maximum | 50 mA |
| SRF minimum | 165 MHz |
| Test frequency | 25 MHz |
| Test voltage | 50 mV |
| Package | 1.6 x 0.8 mm |
| Size code | 1608 (0603) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11101 |

Drawing reproduced from Eaton Technical Data 11101: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
The inductance here is a few nanohenry, which puts the part in RF and high-speed digital territory: matching networks, filter sections, bias chokes on amplifier supplies, and the small isolation inductors that keep clock harmonics out of connectors. The multilayer body keeps the parasitics predictable, and the Q column tells you how much loss the part adds at the test frequency.
The row reads 0.18 nH ±10 with a minimum Q of 20 at 25 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 20 means the part’s loss is about 5 % of its reactance in that band.
Self-resonance is quoted as 165 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 165 MHz is the design headroom.
Within the MCQ1V1608 family this is value 8 of 24, in a range that runs from 0.047 to 3.9 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
How much does the value drift with temperature?
The data sheet gives the tolerance band; the drift inside that band is small for this construction because there is no mechanical winding to move.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Shenzhen Gaorunxin Technology Co., Ltd