| Parameter | Value |
|---|---|
| Orderable part number | MCQ1V3216-R082-R |
| Inductance | 0.082 nH ±10 |
| Q minimum | 30 |
| DCR maximum @ +25 °C | 250 mOhm |
| Rated current maximum | 300 mA |
| SRF minimum | 280 MHz |
| Test frequency | 50 MHz |
| Test voltage | 50 mV |
| Package | 3.2 x 1.6 mm |
| Size code | 3216 (1206) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11102 |

Drawing reproduced from Eaton Technical Data 11102: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
Where a circuit needs a small, stable inductance in a package measured in millimetres, the multilayer chip is the default. Its self-resonant frequency is the practical ceiling – above it the part behaves like a capacitor, so the SRF column is the first thing to check against the operating band.
The row reads 0.082 nH ±10 with a minimum Q of 30 at 50 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 30 means the part’s loss is about 3.33 % of its reactance in that band.
Self-resonance is quoted as 280 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 280 MHz is the design headroom.
Within the MCQ1V3216 family this is value 4 of 25, in a range that runs from 0.047 to 4.7 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Why is the inductance quoted at a test frequency?
At nanohenry values the parasitic capacitance and the measurement fixture both matter. The value is only meaningful at the frequency stated, and the Q column tells you how much of the reactance is loss at that point.
Shenzhen Gaorunxin Technology Co., Ltd