| Parameter | Value |
|---|---|
| Orderable part number | MCQ1V3216-R820-R |
| Inductance | 0.82 nH ±10 |
| Q minimum | 30 |
| DCR maximum @ +25 °C | 600 mOhm |
| Rated current maximum | 150 mA |
| SRF minimum | 100 MHz |
| Test frequency | 25 MHz |
| Test voltage | 50 mV |
| Package | 3.2 x 1.6 mm |
| Size code | 3216 (1206) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, -R suffix |
| Data sheet | Eaton Technical Data 11102 |

Drawing reproduced from Eaton Technical Data 11102: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.
A multilayer chip inductor is a coil printed in layers of ceramic and metal, fired into a single body. There is no winding to buzz or shift, the inductance is set by the printed pattern, and the part sits on the board like any other 0402 or 0603 component. That construction is why these parts are used wherever the value is small and the quantity is large.
The row reads 0.82 nH ±10 with a minimum Q of 30 at 25 MHz. Q is the ratio of reactance to resistance at that frequency, so a Q of 30 means the part’s loss is about 3.33 % of its reactance in that band.
Self-resonance is quoted as 100 MHz minimum. Below it the part is inductive; above it the inter-layer capacitance takes over. The margin between the operating band and 100 MHz is the design headroom.
Within the MCQ1V3216 family this is value 16 of 25, in a range that runs from 0.047 to 4.7 nH.
The multilayer chip family covers nanohenry to a few microhenry values in 0402 through 1812 bodies. It is the range where the inductance is too small for a wound part to be practical and where the self-resonant frequency sets the usable band.
What happens above the self-resonant frequency?
The part becomes capacitive. Any filter or matching design has to keep the operating band below SRF, with margin for the tolerance of the value.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.
Can I replace a wire-wound chip with this part?
Only if the Q and the current rating suit the circuit. Multilayer parts have lower Q and lower current capability than wire-wound parts of the same size.