Eaton MDA-2-1/2-R 2.5 A 250 Vac Ceramic Time-Delay Fuse
Eaton MDA-2-1/2-R 2.5 A 250 Vac Ceramic Time-Delay Fuse

Eaton MDA-2-1/2-R 2.5 A 250 Vac Ceramic Time-Delay Fuse

Share
pEaton MDA-2-1/2-R — 2.5 A, 250 V, time-delay ceramic cartridge fuse, 200 A at 250 Vac; 10,000 A at 125 Vac interrupting./p
    • Product Details
    • Download

    Eaton MDA-2-1/2-R 2.5 A 250 Vac Ceramic Time-Delay Fuse

    Eaton MDA-2-1/2-R 2.5 A 250 Vac Ceramic Time-Delay Fuse belongs to the Eaton range. It carries 2.5 A, rated 125 Vdc, uses a time-delay element, in a ceramic body.

    Technical Data

    ParameterRating
    Part numberMDA-2-1/2-R
    Typical DC cold resistance66 mΩ
    BodyCeramic tube, 1/4 x 1-1/4 in (6.3 x 32 mm)
    Design standardUL 248-14
    Voltage rating, DC125 Vdc
    AC interrupting rating200 A at 250 Vac; 10,000 A at 125 Vac
    Rated current2.5 A (2-1/2 A)
    Typical melting I2t7.2 A²s
    End capsnickel-plated brass
    Elementsingle element
    Maximum voltage drop246 mV
    Voltage rating250 Vac

    Design Notes

    • Interrupting capability is 200 A at 250 Vac; 10,000 A at 125 Vac — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 125 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 2.5 A to stop nuisance trips — fix the cause instead.

    Where It Is Used

    Typical places this fuse turns up:

    • EV

    Common Questions

    What are the ratings of the MDA-2-1/2-R?

    2.5 A continuous at 125 Vdc, interrupting rating 200 A at 250 Vac; 10,000 A at 125 Vac.

    Is the MDA-2-1/2-R fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the MDA-2-1/2-R be used on a higher fault-current circuit?

    No — its interrupting rating is 200 A at 250 Vac; 10,000 A at 125 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.