| Parameter | Rating |
|---|---|
| Part number | MDQ-3/16 |
| Typical DC cold resistance | 10 Ω |
| Body | Glass tube, 1/4 x 1-1/4 in (6.3 x 32 mm) |
| Breaking capacity | 35 A at 250 Vac up to 1 A, 100 A to 7 A, 1,000 A at 32 V above |
| Rated current | 187.5 mA (3/16 A) |
| Element | dual element |
| Voltage rating | 250 Vac |
| AC interrupting rating | 35 A at 250 Vac |
| End caps | nickel-plated brass |
| Design standard | UL 248-14 |
Typical places this fuse turns up:
What are the ratings of the MDQ-3/16?
187.5 mA continuous at 250 Vac, interrupting rating 35 A at 250 Vac.
Is the MDQ-3/16 fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the MDQ-3/16 be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at 250 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.