MLVA04V14C090: multilayer varistor ESD suppressor, 14.4-21.6 V varistor voltage, 14 V working, 38 V clamp, 90 pF, 0.05 J.
    • Product Details
    • Download

    Eaton MLVA04V14C090 MLV ESD Suppressor 90 pF

    MLVA04V14C090 at a glance: multilayer varistor ESD suppressor, 14.4-21.6 V varistor voltage, 14 V working, 38 V clamp, 90 pF, 0.05 J.

    Key Specifications

    ParameterValue
    Orderable part numberMLVA04V14C090
    Package size0402
    Working voltage, RMS11 Vrms
    Working voltage, DC14 Vdc
    Varistor voltage at 1 mA14.4-21.6 V
    Clamping voltage38 V
    Typical capacitance90 pF
    Peak current20 A
    Transient energy0.05 J
    Package0402 (1005 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 4070

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    In a multilayer construction the zinc oxide grains are stacked in many thin layers, so the same body height gives a higher voltage per unit area than a single-layer disc. That is how an 0402 chip reaches 18 Vdc working voltage without becoming thick.

    The clamp column works out at 2.64 times the varistor voltage: 38 V at the rated current against 14.4-21.6 V at 1 mA. That ratio is what the downstream part has to survive, not the 14.4-21.6 V figure on the label.

    The 90 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVA family this is item 6 of 12 in the Eaton catalogue.

    Where This Series Fits

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.