| Parameter | Value |
|---|---|
| Orderable part number | MLVA04V18C085 |
| Package size | 0402 |
| Working voltage, RMS | 14 Vrms |
| Working voltage, DC | 18 Vdc |
| Varistor voltage at 1 mA | 17.6-26.4 V |
| Clamping voltage | 45 V |
| Typical capacitance | 85 pF |
| Peak current | 20 A |
| Transient energy | 0.05 J |
| Package | 0402 (1005 metric) |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +85 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 4070 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
In a multilayer construction the zinc oxide grains are stacked in many thin layers, so the same body height gives a higher voltage per unit area than a single-layer disc. That is how an 0402 chip reaches 18 Vdc working voltage without becoming thick.
The clamp column works out at 2.56 times the varistor voltage: 45 V at the rated current against 17.6-26.4 V at 1 mA. That ratio is what the downstream part has to survive, not the 17.6-26.4 V figure on the label.
The 85 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the MLVA family this is item 7 of 12 in the Eaton catalogue.
The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.
What happens if the part is run above its working voltage?
Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.
Does the package size change the electrical ratings?
Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.
Is the varistor voltage the same as the working voltage?
No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.