Eaton MLVA06V09C210-R Multilayer Varistor, 41 V Clamp
Eaton MLVA06V09C210-R Multilayer Varistor, 41 V Clamp

Eaton MLVA06V09C210-R Multilayer Varistor, 41 V Clamp

Share
MLVA06V09C210-R: multilayer varistor ESD suppressor, 11.5-21.5 V varistor voltage, 9 V working, 41 V clamp, 210 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVA06V09C210-R Multilayer Varistor, 41 V Clamp

    MLVA06V09C210-R at a glance: multilayer varistor ESD suppressor, 11.5-21.5 V varistor voltage, 9 V working, 41 V clamp, 210 pF, 0.1 J.

    Key Specifications

    ParameterValue
    Orderable part numberMLVA06V09C210-R
    Package size0603
    Working voltage, RMS7 Vrms
    Working voltage, DC9 Vdc
    Varistor voltage at 1 mA11.5-21.5 V
    Clamping voltage41 V
    Typical capacitance210 pF
    Peak current30 A
    Transient energy0.1 J
    Package0603 (1608 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 10493

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    Multilayer varistors are chosen for board-level ESD and cable-transient protection where a TVS diode would add capacitance. The trade is a softer clamp: the varistor voltage tolerance is wide, so the clamp column, not the nominal voltage, sets the protection level.

    The clamp column works out at 3.57 times the varistor voltage: 41 V at the rated current against 11.5-21.5 V at 1 mA. That ratio is what the downstream part has to survive, not the 11.5-21.5 V figure on the label.

    The 210 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVA-R family this is item 8 of 10 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.