Eaton MLVA06V26C100-R MLV ESD Suppressor 100 pF
Eaton MLVA06V26C100-R MLV ESD Suppressor 100 pF

Eaton MLVA06V26C100-R MLV ESD Suppressor 100 pF

Share
MLVA06V26C100-R: multilayer varistor ESD suppressor, 32-42 V varistor voltage, 26 V working, 70 V clamp, 100 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVA06V26C100-R MLV ESD Suppressor 100 pF

    MLVA06V26C100-R at a glance: multilayer varistor ESD suppressor, 32-42 V varistor voltage, 26 V working, 70 V clamp, 100 pF, 0.1 J.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVA06V26C100-R
    Package size0603
    Working voltage, RMS20 Vrms
    Working voltage, DC26 Vdc
    Varistor voltage at 1 mA32-42 V
    Clamping voltage70 V
    Typical capacitance100 pF
    Peak current30 A
    Transient energy0.1 J
    Package0603 (1608 metric)
    MountingSurface mount
    Operating temperature-40 °C to +85 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 10493

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    The Figures Explained

    A multilayer varistor sits across a signal or supply rail and does nothing until the voltage crosses its breakdown point, at which it turns into a low impedance and diverts the transient. The value that matters for the protected chip is not the varistor voltage but the clamping voltage at the surge current you expect.

    The clamp column works out at 2.19 times the varistor voltage: 70 V at the rated current against 32-42 V at 1 mA. That ratio is what the downstream part has to survive, not the 32-42 V figure on the label.

    The 100 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVA-R family this is item 10 of 10 in the Eaton catalogue.

    What This Family Is For

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.