| Parameter | Value |
|---|---|
| Orderable part number | MLVB04V18C003 |
| Package size | 0402 |
| Working voltage, DC | 18 Vdc |
| Varistor voltage at 1 mA | 22-34 V |
| Clamping voltage | 58 V |
| Typical capacitance | 3 pF |
| Leakage current | max. 10 uA |
| Package | 0402 (1005 metric) |
| Mounting | Surface mount |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 4071 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
A chip varistor is a ceramic body with two metal terminations, so it looks like a capacitor and behaves like one until the transient arrives. That is why the capacitance column is quoted on every page: it is the parameter that decides whether the part can sit on a data line.
The clamp column works out at 2.64 times the varistor voltage: 58 V at the rated current against 22-34 V at 1 mA. That ratio is what the downstream part has to survive, not the 22-34 V figure on the label.
Standing at 18 V the leakage is at most 10 uA, which is 0.18 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.
The 3 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the MLVB family this is item 3 of 8 in the Eaton catalogue.
The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.
Why is the DC rating lower than the AC rating on some parts?
It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.
Can it protect a differential pair?
Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.
What happens if the part is run above its working voltage?
Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.