Eaton MLVC08V022C175 Multilayer Varistor, 53 V Clamp
Eaton MLVC08V022C175 Multilayer Varistor, 53 V Clamp

Eaton MLVC08V022C175 Multilayer Varistor, 53 V Clamp

Share
MLVC08V022C175: multilayer varistor ESD suppressor, 30 V varistor voltage, 22 V working, 53 V clamp, 175 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVC08V022C175 Multilayer Varistor, 53 V Clamp

    MLVC08V022C175 at a glance: multilayer varistor ESD suppressor, 30 V varistor voltage, 22 V working, 53 V clamp, 175 pF, 0.1 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMLVC08V022C175
    Working voltage, DC22 Vdc
    Working voltage, AC15.6 Vac
    Varistor voltage at 1 mA30 V ±10%
    Clamping voltage at 1 A53 V
    Energy absorption, 10/1000 us0.1 J
    Peak current, 8/20 us35 A
    Typical capacitance at 1 MHz175 pF
    Package0805 (2012 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11237

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    The Figures Explained

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 1.77 times the varistor voltage: 53 V at the rated current against 30 V at 1 mA. That ratio is what the downstream part has to survive, not the 30 V figure on the label.

    The 175 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC general type family this is item 18 of 41 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The varistor voltage tolerance is wide by design. Two parts of the same part number can differ by 20 percent and both be good, so the design has to work at the low end of the range.

    Frequently Asked Questions

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products