MLVC08V033C230: multilayer varistor ESD suppressor, 45 V varistor voltage, 33 V working, 79 V clamp, 230 pF, 0.3 J.
    • Product Details
    • Download

    Eaton MLVC08V033C230 Multilayer Varistor, 79 V Clamp

    MLVC08V033C230 at a glance: multilayer varistor ESD suppressor, 45 V varistor voltage, 33 V working, 79 V clamp, 230 pF, 0.3 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVC08V033C230
    Working voltage, DC33 Vdc
    Working voltage, AC23.3 Vac
    Varistor voltage at 1 mA45 V ±10%
    Clamping voltage at 1 A79 V
    Energy absorption, 10/1000 us0.3 J
    Peak current, 8/20 us35 A
    Typical capacitance at 1 MHz230 pF
    Package0805 (2012 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    In a multilayer construction the zinc oxide grains are stacked in many thin layers, so the same body height gives a higher voltage per unit area than a single-layer disc. That is how an 0402 chip reaches 18 Vdc working voltage without becoming thick.

    The clamp column works out at 1.76 times the varistor voltage: 79 V at the rated current against 45 V at 1 mA. That ratio is what the downstream part has to survive, not the 45 V figure on the label.

    The 230 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 9 of 97 in the Eaton catalogue.

    Positioning in the Range

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.