MLVC08V042C100: multilayer varistor ESD suppressor, 56 V varistor voltage, 42 V working, 99 V clamp, 100 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVC08V042C100 MLV ESD Suppressor 100 pF

    MLVC08V042C100 at a glance: multilayer varistor ESD suppressor, 56 V varistor voltage, 42 V working, 99 V clamp, 100 pF, 0.1 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMLVC08V042C100
    Working voltage, DC42 Vdc
    Working voltage, AC30 Vac
    Varistor voltage at 1 mA56 V ±10%
    Clamping voltage at 1 A99 V
    Energy absorption, 10/1000 us0.1 J
    Peak current, 8/20 us35 A
    Typical capacitance at 1 MHz100 pF
    Package0805 (2012 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11237

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    In a multilayer construction the zinc oxide grains are stacked in many thin layers, so the same body height gives a higher voltage per unit area than a single-layer disc. That is how an 0402 chip reaches 18 Vdc working voltage without becoming thick.

    The clamp column works out at 1.77 times the varistor voltage: 99 V at the rated current against 56 V at 1 mA. That ratio is what the downstream part has to survive, not the 56 V figure on the label.

    The 100 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC general type family this is item 24 of 41 in the Eaton catalogue.

    Series Positioning

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.