Eaton MLVC12V030C200 1206 Chip Varistor 30 Vdc
Eaton MLVC12V030C200 1206 Chip Varistor 30 Vdc

Eaton MLVC12V030C200 1206 Chip Varistor 30 Vdc

Share
MLVC12V030C200: multilayer varistor ESD suppressor, 42 V varistor voltage, 30 V working, 74 V clamp, 200 pF, 0.1 J.
    • Product Details
    • Download

    Eaton MLVC12V030C200 1206 Chip Varistor 30 Vdc

    MLVC12V030C200 at a glance: multilayer varistor ESD suppressor, 42 V varistor voltage, 30 V working, 74 V clamp, 200 pF, 0.1 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMLVC12V030C200
    Working voltage, DC30 Vdc
    Working voltage, AC21.2 Vac
    Varistor voltage at 1 mA42 V ±10%
    Clamping voltage at 1 A74 V
    Energy absorption, 10/1000 us0.1 J
    Peak current, 8/20 us35 A
    Typical capacitance at 1 MHz200 pF
    Package1206 (3216 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11237

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    These parts are zinc oxide ceramics sintered into a chip, so the response is faster than a junction device and there is no wear-out mechanism below the rated energy. What does degrade them is repeated energy above the rating, which shows up as a falling varistor voltage.

    The clamp column works out at 1.76 times the varistor voltage: 74 V at the rated current against 42 V at 1 mA. That ratio is what the downstream part has to survive, not the 42 V figure on the label.

    The 200 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC general type family this is item 33 of 41 in the Eaton catalogue.

    Series Positioning

    The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.

    • The energy rating assumes a single pulse. Repeating the same transient heats the body faster than the datasheet curve suggests, because the curve is drawn for one event at a time.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.