MLVC13V056C450: multilayer varistor ESD suppressor, 72 V varistor voltage, 56 V working, 127 V clamp, 450 pF, 1.5 J.
    • Product Details
    • Download

    Eaton MLVC13V056C450 Multilayer Varistor, 127 V Clamp

    MLVC13V056C450 at a glance: multilayer varistor ESD suppressor, 72 V varistor voltage, 56 V working, 127 V clamp, 450 pF, 1.5 J.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVC13V056C450
    Working voltage, DC56 Vdc
    Working voltage, AC40 Vac
    Varistor voltage at 1 mA72 V ±10%
    Clamping voltage at 1 A127 V
    Energy absorption, 10/1000 us1.5 J
    Peak current, 8/20 us250 A
    Typical capacitance at 1 MHz450 pF
    Package1210 (3225 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 1.76 times the varistor voltage: 127 V at the rated current against 72 V at 1 mA. That ratio is what the downstream part has to survive, not the 72 V figure on the label.

    The 450 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 37 of 97 in the Eaton catalogue.

    What This Family Is For

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.