Eaton MLVC22V026C2500 26 V Multilayer Varistor
Eaton MLVC22V026C2500 26 V Multilayer Varistor

Eaton MLVC22V026C2500 26 V Multilayer Varistor

Share
MLVC22V026C2500: multilayer varistor ESD suppressor, 36 V varistor voltage, 26 V working, 63 V clamp, 2500 pF, 2.5 J.
    • Product Details
    • Download

    Eaton MLVC22V026C2500 26 V Multilayer Varistor

    MLVC22V026C2500 at a glance: multilayer varistor ESD suppressor, 36 V varistor voltage, 26 V working, 63 V clamp, 2500 pF, 2.5 J.

    Key Specifications

    ParameterValue
    Orderable part numberMLVC22V026C2500
    Working voltage, DC26 Vdc
    Working voltage, AC18.4 Vac
    Varistor voltage at 1 mA36 V ±10%
    Clamping voltage at 1 A63 V
    Energy absorption, 10/1000 us2.5 J
    Peak current, 8/20 us600 A
    Typical capacitance at 1 MHz2500 pF
    Package2220 (5750 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 1.75 times the varistor voltage: 63 V at the rated current against 36 V at 1 mA. That ratio is what the downstream part has to survive, not the 36 V figure on the label.

    The 2500 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 58 of 97 in the Eaton catalogue.

    Where This Series Fits

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • Do not run the part at its varistor voltage: the working voltage column is the continuous limit, and the varistor voltage is 1.5 to 2 times higher only because the ceramic is soft at the knee.
    • The varistor voltage tolerance is wide by design. Two parts of the same part number can differ by 20 percent and both be good, so the design has to work at the low end of the range.

    Frequently Asked Questions

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.