Eaton MLVC32V170C400 MLV ESD Suppressor 400 pF
Eaton MLVC32V170C400 MLV ESD Suppressor 400 pF

Eaton MLVC32V170C400 MLV ESD Suppressor 400 pF

Share
MLVC32V170C400: multilayer varistor ESD suppressor, 205 V varistor voltage, 170 V working, 361 V clamp, 400 pF, 4.2 J.
    • Product Details
    • Download

    Eaton MLVC32V170C400 MLV ESD Suppressor 400 pF

    MLVC32V170C400 at a glance: multilayer varistor ESD suppressor, 205 V varistor voltage, 170 V working, 361 V clamp, 400 pF, 4.2 J.

    Electrical Specifications

    ParameterValue
    Orderable part numberMLVC32V170C400
    Working voltage, DC170 Vdc
    Working voltage, AC130 Vac
    Varistor voltage at 1 mA205 V ±10%
    Clamping voltage at 1 A361 V
    Energy absorption, 10/1000 us4.2 J
    Peak current, 8/20 us400 A
    Typical capacitance at 1 MHz400 pF
    Package3225 (8063 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    These parts are zinc oxide ceramics sintered into a chip, so the response is faster than a junction device and there is no wear-out mechanism below the rated energy. What does degrade them is repeated energy above the rating, which shows up as a falling varistor voltage.

    The clamp column works out at 1.76 times the varistor voltage: 361 V at the rated current against 205 V at 1 mA. That ratio is what the downstream part has to survive, not the 205 V figure on the label.

    The 400 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 79 of 97 in the Eaton catalogue.

    Where This Series Fits

    Place it on the connector side of any series impedance. A varistor behind a common-mode choke protects the choke and not the connector, which is usually the wrong way round.

    • Do not run the part at its varistor voltage: the working voltage column is the continuous limit, and the varistor voltage is 1.5 to 2 times higher only because the ceramic is soft at the knee.
    • The capacitance column is the price of the protection: a 20000 pF part will load a high speed data line, which is why the low-capacitance versions exist at the same voltage.

    Frequently Asked Questions

    What happens if the part is run above its working voltage?
    Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.

    Does the package size change the electrical ratings?
    Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.

    Is the varistor voltage the same as the working voltage?
    No. The working voltage is the continuous DC or AC level the part can sit at; the varistor voltage is measured at 1 mA and is typically 1.5 to 2 times higher. Sizing on the varistor voltage would put the part into conduction on a normal rail.