Eaton MLVC40V125C1350 Multilayer Varistor, 264 V Clamp
Eaton MLVC40V125C1350 Multilayer Varistor, 264 V Clamp

Eaton MLVC40V125C1350 Multilayer Varistor, 264 V Clamp

Share
MLVC40V125C1350: multilayer varistor ESD suppressor, 150 V varistor voltage, 125 V working, 264 V clamp, 1350 pF, 7.6 J.
    • Product Details
    • Download

    Eaton MLVC40V125C1350 Multilayer Varistor, 264 V Clamp

    MLVC40V125C1350 at a glance: multilayer varistor ESD suppressor, 150 V varistor voltage, 125 V working, 264 V clamp, 1350 pF, 7.6 J.

    Specification Table

    ParameterValue
    Orderable part numberMLVC40V125C1350
    Working voltage, DC125 Vdc
    Working voltage, AC95 Vac
    Varistor voltage at 1 mA150 V ±10%
    Clamping voltage at 1 A264 V
    Energy absorption, 10/1000 us7.6 J
    Peak current, 8/20 us1200 A
    Typical capacitance at 1 MHz1350 pF
    Package4032 (10280 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    Multilayer varistors are chosen for board-level ESD and cable-transient protection where a TVS diode would add capacitance. The trade is a softer clamp: the varistor voltage tolerance is wide, so the clamp column, not the nominal voltage, sets the protection level.

    The clamp column works out at 1.76 times the varistor voltage: 264 V at the rated current against 150 V at 1 mA. That ratio is what the downstream part has to survive, not the 150 V figure on the label.

    The 1350 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 93 of 97 in the Eaton catalogue.

    Positioning in the Range

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • A varistor is not a zener. It has no sharp knee, so it conducts a little at the working voltage and the leakage column is the honest measure of that.
    • The response time is quoted below a nanosecond because the ceramic turns conductive in the grain boundaries, not because of a junction.

    Frequently Asked Questions

    What does the capacitance do to my signal?
    It loads the line. At 1 MHz a 100 pF part is about 1.6 kOhm of reactance, which is harmless on a power rail and fatal on a 480 Mbit USB pair. Choose a low-capacitance version when the line carries data.

    How many ESD strikes can it take?
    The ESD rating is a qualification level, not a lifetime count. IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive repeated strikes at that level because the energy per strike is small.

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.