MLVC40V170C900: multilayer varistor ESD suppressor, 205 V varistor voltage, 170 V working, 361 V clamp, 900 pF, 9.5 J.
    • Product Details
    • Download

    Eaton MLVC40V170C900 MLV ESD Suppressor 900 pF

    MLVC40V170C900 at a glance: multilayer varistor ESD suppressor, 205 V varistor voltage, 170 V working, 361 V clamp, 900 pF, 9.5 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMLVC40V170C900
    Working voltage, DC170 Vdc
    Working voltage, AC130 Vac
    Varistor voltage at 1 mA205 V ±10%
    Clamping voltage at 1 A361 V
    Energy absorption, 10/1000 us9.5 J
    Peak current, 8/20 us1200 A
    Typical capacitance at 1 MHz900 pF
    Package4032 (10280 metric)
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11236

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    The working voltage is the DC or AC level the part can sit at continuously without conducting appreciably. Pick it above the highest steady-state rail voltage including tolerance, and let the clamp column decide whether the downstream part survives the surge.

    The clamp column works out at 1.76 times the varistor voltage: 361 V at the rated current against 205 V at 1 mA. That ratio is what the downstream part has to survive, not the 205 V figure on the label.

    The 900 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.

    Within the MLVC high energy family this is item 95 of 97 in the Eaton catalogue.

    Positioning in the Range

    The return path is half the component. A varistor tied to a ground plane far from the connector leaves the loop inductance in series with the clamp, and the residual voltage at the chip is the clamp plus L di/dt.

    • Do not use a varistor as a series element or in a signal path carrying DC. It is a shunt device, and any steady current through it is a fault.
    • The varistor voltage tolerance is wide by design. Two parts of the same part number can differ by 20 percent and both be good, so the design has to work at the low end of the range.

    Frequently Asked Questions

    Does the clamp voltage scale with the surge current?
    Yes. The clamp column is quoted at a stated current, usually 1 A. At ten times that current the residual voltage is higher, so read the V-I curve rather than the single number when the surge is large.

    Why is the DC rating lower than the AC rating on some parts?
    It is not, on these: the AC rating is an RMS value, so the DC rating is set at the peak of that sine plus margin. Where the two look inconsistent, check which one is quoted as RMS.

    Can it protect a differential pair?
    Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.