| Parameter | Value |
|---|---|
| Orderable part number | MLVHV0806V300 |
| Working voltage, AC | 300 Vac |
| Working voltage, DC | 385 Vdc |
| Varistor voltage at 1 mA | 470 V ±10% |
| Leakage current at 0.8 Vv | max. 50 uA |
| Clamping voltage at 1 A | 740 V |
| Typical capacitance at 1 kHz | 15 pF |
| Peak current, 8/20 us (1 pulse) | 10 A |
| Peak current, 8/20 us (15 pulses) | 10 A |
| Package | 0806 chip |
| Mounting | Surface mount |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1239 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
Multilayer varistors are chosen for board-level ESD and cable-transient protection where a TVS diode would add capacitance. The trade is a softer clamp: the varistor voltage tolerance is wide, so the clamp column, not the nominal voltage, sets the protection level.
The clamp column works out at 1.57 times the varistor voltage: 740 V at the rated current against 470 V at 1 mA. That ratio is what the downstream part has to survive, not the 470 V figure on the label.
Standing at 385 V the leakage is at most 50 uA, which is 19.25 mW of continuous dissipation. Small, but it is why a varistor on a battery rail has to be chosen on leakage and not only on voltage.
The 15 pF typical capacitance is the cost of the clamp. On a power rail it is irrelevant; on a data line it is the reason to look at the low-capacitance versions of the same voltage.
Within the MLVHV family this is item 5 of 5 in the Eaton catalogue.
The part goes across the line it protects, as close to the connector or the cable entry as the layout allows. Lead length matters: every extra millimetre of trace between the connector and the varistor adds inductance and raises the voltage the protected chip actually sees.
Can it protect a differential pair?
Only with a low-capacitance part and a layout that keeps both lines symmetric. A single varistor from each line to ground is normal; one across the pair is not, because it unbalances the pair.
What happens if the part is run above its working voltage?
Leakage rises steeply and the body heats. A varistor is not a clamp with a sharp knee, so continuous operation above the rating is a slow degradation, not an immediate failure.
Does the package size change the electrical ratings?
Yes, the energy and peak current scale with the body volume, so a 0402 and a 1206 of the same voltage are not interchangeable on a surge.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd