| Parameter | Value |
|---|---|
| Orderable part number | MOV07V385 |
| Varistor voltage at 1 mA | 620 V |
| Maximum continuous AC voltage | 385 Vrms |
| Maximum continuous DC voltage | 505 Vdc |
| Clamping voltage | 1025 V |
| Clamping current | 10 A |
| Maximum surge current, 8/20 us | 1200 A |
| Rated power | 0.25 W |
| Typical capacitance at 1 kHz | 80 pF |
| Maximum energy, 10/1000 us | 38 J |
| Maximum body diameter | 6 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 7 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1287 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
The disc is coated in epoxy and marked with the part number and the varistor voltage. Because the body is the component, the lead spacing and the disc diameter together decide the footprint – there is no separate package to shrink around it.
The clamp column works out at 1.65 times the varistor voltage: 1025 V at the rated current against 620 V at 1 mA. That ratio is what the downstream part has to survive, not the 620 V figure on the label.
The disc absorbs 38 J in a 10/1000 us pulse and carries 1200 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 0.25 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 80 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOV family this is item 13 of 71 in the Eaton catalogue.
Mount it with the body clear of the transformer and the bridge rectifier; a disc running at its rated power needs air, and the derating curve assumes it gets some.
Why is the DC rating higher than the AC rating?
The AC rating is an RMS value, so the peak of the sine is 1.41 times higher. The DC rating is set at that peak plus margin, which is why a 130 Vac part is rated 170 Vdc.
What happens at end of life?
A varistor that absorbs more than its rating drifts low in voltage and eventually fails short. That is why a fuse or a thermal element is placed in series with it on mains inputs.
Can it be used on a DC bus?
Yes, within the DC rating, but the energy per event is usually larger because there is no zero crossing to help extinguish the follow current. Check the application note before using a mains part on a high-voltage DC bus.