| Parameter | Value |
|---|---|
| Orderable part number | MOV10V230 |
| Varistor voltage at 1 mA | 360 V |
| Maximum continuous AC voltage | 230 Vrms |
| Maximum continuous DC voltage | 300 Vdc |
| Clamping voltage | 595 V |
| Clamping current | 25 A |
| Maximum surge current, 8/20 us | 2500 A |
| Rated power | 0.4 W |
| Typical capacitance at 1 kHz | 280 pF |
| Maximum energy, 10/1000 us | 47 J |
| Maximum body diameter | 5 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 10 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1287 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
For AC mains service the continuous rating is given as an RMS voltage, and the DC rating is that value multiplied by roughly 1.41. Sizing the part at or near the nominal line voltage leaves no room for regulation tolerance or a prolonged overvoltage, so the usual rule is 10 to 20 percent headroom.
The clamp column works out at 1.65 times the varistor voltage: 595 V at the rated current against 360 V at 1 mA. That ratio is what the downstream part has to survive, not the 360 V figure on the label.
The disc absorbs 47 J in a 10/1000 us pulse and carries 2500 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 0.4 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 280 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOV family this is item 22 of 71 in the Eaton catalogue.
Keep the leads short and do not sleeve them together: the loop area between the two leads is part of the clamping path, and folding them against each other is what keeps the inductance low.
Can it be used on a DC bus?
Yes, within the DC rating, but the energy per event is usually larger because there is no zero crossing to help extinguish the follow current. Check the application note before using a mains part on a high-voltage DC bus.
How do I choose between 130 V and 150 V for a 120 V line?
On a 120 V nominal line the steady-state RMS can reach 132 V or more, so a 130 Vac part has no headroom. The 150 V part is the usual choice, and the varistor voltage that comes with it is still below the withstand of most downstream parts.
Does the lead spacing matter electrically?
It matters mechanically and for inductance. Wider spacing means a larger loop, which adds inductance in series with the clamp; the disc diameter sets the spacing, so the two choices are linked.