Eaton MOVGT07V055K MOV / GDT Device 55 Vac
Eaton MOVGT07V055K MOV / GDT Device 55 Vac

Eaton MOVGT07V055K MOV / GDT Device 55 Vac

Share
MOVGT07V055K: integrated MOV / GDT device, 710 V clamp, 5 pF, 10 J.
    • Product Details
    • Download

    Eaton MOVGT07V055K MOV / GDT Device 55 Vac

    MOVGT07V055K at a glance: integrated MOV / GDT device, 710 V clamp, 5 pF, 10 J.

    Ratings at a Glance

    ParameterValue
    Orderable part numberMOVGT07V055K
    UL volts52 Vac
    Recommended MCOV55 Vac
    UL MCOV70 Vac
    MOV voltage at 1 mA82(74~90) V
    GDT voltage at 100 V/s90(72~108) V
    Platform voltage at 1000 V/usmax. 150 V
    Peak voltage at 1000 V/usmax. 710 V
    Withstand count at 2 kV / 1 kA40 shots
    MOV withstand current, 8/20 us1750 A
    Maximum energy, 10/1000 us10 J
    Capacitance at 1 kHz5 pF
    Package7 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1161

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    What the Numbers Mean

    A gas discharge tube has a very low clamp but a slow, unpredictable trigger; a MOV has a fast trigger but a higher clamp. Putting them in series lets the MOV start the conduction and the GDT take the bulk of the current, which drops the residual voltage without losing the speed.

    The MOV inside is a 82(74~90) V part and the GDT is a 90(72~108) V tube. In series the pair holds the surge at the platform voltage of 150 V, well under the peak 710 V it would reach alone at a 1000 V/us edge.

    Withstand is quoted as 40 shots at 2 kV / 1 kA. Because the GDT carries the follow current, the MOV is not eroded by the long tail of the pulse the way a stand-alone varistor is.

    Within the MOVGT family this is item 1 of 160 in the Eaton catalogue.

    Series Positioning

    The series combination goes across the input at the first stage, ahead of the filter, with the GDT on the line side. Both devices carry the surge current, so the trace between them has to be as short and as wide as the incoming conductor.

    • A GDT has a statistical sparkover. The tolerance in the table is the spread over many units, not the repeatability of one unit.
    • The platform voltage is the level the combination holds during the surge; size the downstream insulation against it, not against the GDT DC sparkover.

    Frequently Asked Questions

    What keeps the GDT from firing on the normal line voltage?
    The MOV holds off the continuous voltage, so the GDT only sees the line when the MOV is conducting. That coordination is what allows the series stack to sit across mains.

    How many surges will it take?
    The withstand column states the count at 2 kV / 1 kA, typically 40 shots. That is the number to design against, not the single-shot peak current of the MOV inside.

    Can it be used on DC?
    No. A GDT does not extinguish below its arc voltage, so on DC the follow current continues until the source is removed. This part is for AC mains input.