Eaton MOVGT07V120K MOV / GDT Device 120 Vac
Eaton MOVGT07V120K MOV / GDT Device 120 Vac

Eaton MOVGT07V120K MOV / GDT Device 120 Vac

Share
MOVGT07V120K: integrated MOV / GDT device, 710 V clamp, 5 pF, 16 J.
    • Product Details
    • Download

    Eaton MOVGT07V120K MOV / GDT Device 120 Vac

    MOVGT07V120K at a glance: integrated MOV / GDT device, 710 V clamp, 5 pF, 16 J.

    Specification Table

    ParameterValue
    Orderable part numberMOVGT07V120K
    UL volts115 Vac
    Recommended MCOV120 Vac
    UL MCOV150 Vac
    MOV voltage at 1 mA180(162~198) V
    GDT voltage at 100 V/s90(72~108) V
    Platform voltage at 1000 V/usmax. 320 V
    Peak voltage at 1000 V/usmax. 710 V
    Withstand count at 2 kV / 1 kA40 shots
    MOV withstand current, 8/20 us1750 A
    Maximum energy, 10/1000 us16 J
    Capacitance at 1 kHz5 pF
    Package7 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1161

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    Reading the Data Sheet

    The part is coordinated so the GDT does not see the continuous line voltage: the MOV holds off the normal operating level and the GDT only fires inside a surge. That is what makes the series connection possible at mains voltages.

    The MOV inside is a 180(162~198) V part and the GDT is a 90(72~108) V tube. In series the pair holds the surge at the platform voltage of 320 V, well under the peak 710 V it would reach alone at a 1000 V/us edge.

    Withstand is quoted as 40 shots at 2 kV / 1 kA. Because the GDT carries the follow current, the MOV is not eroded by the long tail of the pulse the way a stand-alone varistor is.

    Within the MOVGT family this is item 9 of 160 in the Eaton catalogue.

    Positioning in the Range

    The part is the first thing the surge sees, so it sits between the inlet and the fuse only if the fuse is rated for the follow current; otherwise the fuse goes first and the protector after it.

    • The platform voltage is a surge figure, not a continuous rating. Do not use it to size the working voltage of the circuit.
    • The capacitance is a few picofarads, which is low enough for a mains input and low enough not to load a signal pair.

    Frequently Asked Questions

    Is the capacitance low enough for a signal line?
    A few picofarads, yes, but this is a mains protector. Its package and its platform voltage are chosen for an input stage, not for a data pair.

    Why put a GDT in series with a MOV?
    The MOV triggers fast and the GDT clamps low. In series the MOV starts the conduction and the GDT carries the current, so the residual voltage is closer to the GDT arc voltage than to the MOV clamp.

    What keeps the GDT from firing on the normal line voltage?
    The MOV holds off the continuous voltage, so the GDT only sees the line when the MOV is conducting. That coordination is what allows the series stack to sit across mains.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd