Eaton MOVGT20V200K MOVGT Hybrid Protector 20 mm
Eaton MOVGT20V200K MOVGT Hybrid Protector 20 mm

Eaton MOVGT20V200K MOVGT Hybrid Protector 20 mm

Share
MOVGT20V200K: integrated MOV / GDT device, 1020 V clamp, 5 pF, 210 J.
    • Product Details
    • Download

    Eaton MOVGT20V200K MOVGT Hybrid Protector 20 mm

    MOVGT20V200K at a glance: integrated MOV / GDT device, 1020 V clamp, 5 pF, 210 J.

    Key Specifications

    ParameterValue
    Orderable part numberMOVGT20V200K
    UL volts190 Vac
    Recommended MCOV200 Vac
    UL MCOV250 Vac
    MOV voltage at 1 mA300(270~330) V
    GDT voltage at 100 V/s350(280~420) V
    Platform voltage at 1000 V/usmax. 530 V
    Peak voltage at 1000 V/usmax. 1020 V
    Withstand count at 2 kV / 1 kA40 shots
    MOV withstand current, 8/20 us10000 A
    Maximum energy, 10/1000 us210 J
    Capacitance at 1 kHz5 pF
    Package20 mm disc
    MountingRadial, through-hole
    Operating temperature-40 °C to +105 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1161

    Dimensions, recommended pad or hole pattern and the derating curves are
    on the data sheet pages; the package line above gives the body size as Eaton states it.

    How to Read These Ratings

    The two devices are stacked in one package, so the coordination is fixed by the manufacturer rather than by the board designer. That removes the usual risk of picking a GDT whose sparkover sits too close to the MOV clamp.

    The MOV inside is a 300(270~330) V part and the GDT is a 350(280~420) V tube. In series the pair holds the surge at the platform voltage of 530 V, well under the peak 1020 V it would reach alone at a 1000 V/us edge.

    Withstand is quoted as 40 shots at 2 kV / 1 kA. Because the GDT carries the follow current, the MOV is not eroded by the long tail of the pulse the way a stand-alone varistor is.

    Within the MOVGT family this is item 138 of 160 in the Eaton catalogue.

    Positioning in the Range

    The part is the first thing the surge sees, so it sits between the inlet and the fuse only if the fuse is rated for the follow current; otherwise the fuse goes first and the protector after it.

    • The platform voltage is a surge figure, not a continuous rating. Do not use it to size the working voltage of the circuit.
    • The capacitance is a few picofarads, which is low enough for a mains input and low enough not to load a signal pair.

    Frequently Asked Questions

    Why put a GDT in series with a MOV?
    The MOV triggers fast and the GDT clamps low. In series the MOV starts the conduction and the GDT carries the current, so the residual voltage is closer to the GDT arc voltage than to the MOV clamp.

    What keeps the GDT from firing on the normal line voltage?
    The MOV holds off the continuous voltage, so the GDT only sees the line when the MOV is conducting. That coordination is what allows the series stack to sit across mains.

    How many surges will it take?
    The withstand column states the count at 2 kV / 1 kA, typically 40 shots. That is the number to design against, not the single-shot peak current of the MOV inside.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products