
| Parameter | Value |
|---|---|
| Orderable part number | MOVHE10V625 |
| Varistor voltage at 1 mA | 1000 V |
| Maximum continuous AC voltage | 625 Vrms |
| Maximum continuous DC voltage | 825 Vdc |
| Clamping voltage | 1650 V |
| Clamping current | 25 A |
| Maximum surge current, 8/20 us | 3500 A |
| Rated power | 0.4 W |
| Typical capacitance at 1 kHz | 100 pF |
| Maximum energy, 10/1000 us | 140 J |
| Maximum body diameter | 7.5 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 10 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1288 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
This is a single-shot device in the sense that the joule rating is quoted for one pulse. A surge protector built around a disc survives because the pulses are rare, not because the part is unlimited; the derating curve states how many.
The clamp column works out at 1.65 times the varistor voltage: 1650 V at the rated current against 1000 V at 1 mA. That ratio is what the downstream part has to survive, not the 1000 V figure on the label.
The disc absorbs 140 J in a 10/1000 us pulse and carries 3500 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 0.4 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 100 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOVHE family this is item 33 of 71 in the Eaton catalogue.
Mount it with the body clear of the transformer and the bridge rectifier; a disc running at its rated power needs air, and the derating curve assumes it gets some.
What happens at end of life?
A varistor that absorbs more than its rating drifts low in voltage and eventually fails short. That is why a fuse or a thermal element is placed in series with it on mains inputs.
Can it be used on a DC bus?
Yes, within the DC rating, but the energy per event is usually larger because there is no zero crossing to help extinguish the follow current. Check the application note before using a mains part on a high-voltage DC bus.
How do I choose between 130 V and 150 V for a 120 V line?
On a 120 V nominal line the steady-state RMS can reach 132 V or more, so a 130 Vac part has no headroom. The 150 V part is the usual choice, and the varistor voltage that comes with it is still below the withstand of most downstream parts.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd