| Parameter | Value |
|---|---|
| Orderable part number | MOVHE14V130 |
| Varistor voltage at 1 mA | 200 V |
| Maximum continuous AC voltage | 130 Vrms |
| Maximum continuous DC voltage | 170 Vdc |
| Clamping voltage | 340 V |
| Clamping current | 50 A |
| Maximum surge current, 8/20 us | 6000 A |
| Rated power | 0.6 W |
| Typical capacitance at 1 kHz | 1000 pF |
| Maximum energy, 10/1000 us | 70 J |
| Maximum body diameter | 4.5 mm |
| Agency recognition | cURus (UL 1449) and TUV |
| Package | 14 mm disc |
| Mounting | Radial, through-hole |
| Operating temperature | -40 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1288 |
Dimensions, recommended pad or hole pattern and the derating curves are
on the data sheet pages; the package line above gives the body size as Eaton states it.
For AC mains service the continuous rating is given as an RMS voltage, and the DC rating is that value multiplied by roughly 1.41. Sizing the part at or near the nominal line voltage leaves no room for regulation tolerance or a prolonged overvoltage, so the usual rule is 10 to 20 percent headroom.
The clamp column works out at 1.7 times the varistor voltage: 340 V at the rated current against 200 V at 1 mA. That ratio is what the downstream part has to survive, not the 200 V figure on the label.
The disc absorbs 70 J in a 10/1000 us pulse and carries 6000 A in an 8/20 us pulse. Those are single shot figures: the same part will take a fraction of the energy repeatedly.
At 0.6 W continuous rating the body can sit at the working voltage indefinitely. A 20 mm disc handles roughly 1000 pF across the line, which matters on a signal-carrying pair but not on a mains input.
Within the MOVHE family this is item 34 of 71 in the Eaton catalogue.
The varistor sits across the input after the fuse and before the rectifier, with short, thick traces or a direct lead-to-terminal connection. A long return path turns the trace inductance into a voltage spike that the varistor cannot clamp.
Are these parts UL recognised?
Yes, the data sheet lists cURus to UL 1449 and TUV. The file numbers are on the agency page of the data sheet, and they cover the whole family.
How do I size the disc diameter?
From the energy, not the current. Estimate the joule content of the surge your source can deliver, add margin for repeated events, and pick the smallest disc that covers it; a larger disc also raises the capacitance across the line.
Why is the DC rating higher than the AC rating?
The AC rating is an RMS value, so the peak of the sine is 1.41 times higher. The DC rating is set at that peak plus margin, which is why a 130 Vac part is rated 170 Vdc.
Shenzhen Gaorunxin Technology Co., Ltd