Eaton MP2-2R2-R 2.2 uH High-Current Inductor
Eaton MP2-2R2-R 2.2 uH High-Current Inductor

Eaton MP2-2R2-R 2.2 uH High-Current Inductor

Share
MP2-2R2-R: high-current power inductor, 2.2 uH, 1.39 A, Isat 1.4 A, DCR 130 mOhm.
    • Product Details
    • Download

    Eaton MP2-2R2-R 2.2 uH High-Current Inductor

    MP2-2R2-R at a glance: high-current power inductor, 2.2 uH, 1.39 A, Isat 1.4 A, DCR 130 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMP2-2R2-R
    Inductance2.2 uH ±20%
    Q minimum32
    DCR maximum @ +25 °C130 mOhm
    Irms (DC, 40 °C rise)1.39 A
    Isat1.4 A
    SRF typical150 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4108

    Dimensions and Pad Layout

    MP2-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4108: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    What the Numbers Mean

    A shielded power inductor with a soft saturation curve: as the current rises the inductance droops rather than collapsing, so the regulator keeps control through a load transient. The molded body contains the field, which is why these parts can sit side by side on a multiphase rail without coupling into each other.

    At 1.39 A the winding dissipates about 0.251 W in copper, using the 130 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 1.4 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MP2 family this is value 4 of 12, in a range that runs from 0.47 to 47 uH.

    Series Positioning

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: pc cards,; mobile phones; disk drives; gps systems.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.