Eaton MP2-R47-R 0.47 uH Inductor, Isat 3.4 A
Eaton MP2-R47-R 0.47 uH Inductor, Isat 3.4 A

Eaton MP2-R47-R 0.47 uH Inductor, Isat 3.4 A

Share
MP2-R47-R: high-current power inductor, 0.47 uH, 2.02 A, Isat 3.4 A, DCR 75 mOhm.
    • Product Details
    • Download

    Eaton MP2-R47-R 0.47 uH Inductor, Isat 3.4 A

    MP2-R47-R at a glance: high-current power inductor, 0.47 uH, 2.02 A, Isat 3.4 A, DCR 75 mOhm.

    Specification Table

    ParameterValue
    Orderable part numberMP2-R47-R
    Inductance0.47 nH ±20%
    Q minimum10
    DCR maximum @ +25 °C75 mOhm
    Irms (DC, 40 °C rise)2.02 A
    Isat3.4 A
    SRF typical300 MHz
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 4108

    Outline Drawing

    MP2-R47-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 4108: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    The Figures Explained

    This is a surface-mount power inductor for DC-DC conversion. Its two limiting numbers are Irms, which sets the thermal ceiling, and Isat, which sets the current at which inductance has fallen by a defined percentage – both are on the data sheet row and both matter at different points in the load profile.

    At 2.02 A the winding dissipates about 0.306 W in copper, using the 75 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 3.4 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MP2 family this is value 1 of 12, in a range that runs from 0.47 to 47 uH.

    Positioning in the Range

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: pc cards,; mobile phones; disk drives; gps systems.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.

    How much inductance is left at rated current?
    The FLL column gives the inductance at saturation current. Ripple at full load should be calculated with FLL, not with the zero-bias value.