Eaton MPI2010V1-1R0-R 1.0 uH Shielded Inductor 54 mOhm
Eaton MPI2010V1-1R0-R 1.0 uH Shielded Inductor 54 mOhm

Eaton MPI2010V1-1R0-R 1.0 uH Shielded Inductor 54 mOhm

Share
MPI2010V1-1R0-R: high-current power inductor, 1.0 uH, 3.3 A, Isat 3.6 A, DCR 54 mOhm.
    • Product Details
    • Download

    Eaton MPI2010V1-1R0-R 1.0 uH Shielded Inductor 54 mOhm

    MPI2010V1-1R0-R at a glance: high-current power inductor, 1.0 uH, 3.3 A, Isat 3.6 A, DCR 54 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberMPI2010V1-1R0-R
    Inductance1.0 uH ±20%
    DCR maximum @ +25 °C54 mOhm
    Irms (DC, 40 °C rise)3.3 A
    Isat3.6 A
    SRF typical100 MHz
    K-factor2990
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10938

    Mechanical Dimensions & Pad Layout

    MPI2010V1-1R0-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10938: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    What the Numbers Mean

    The part is built around a distributed-gap core: the energy is stored through the volume of the magnetic material rather than in a single discrete gap, which is what produces the gradual rolloff and the low fringing field. Copper loss and core loss are traded against each other in the winding and body proportions.

    At 3.3 A the winding dissipates about 0.588 W in copper, using the 54 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 3.6 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MPI2010V1 family this is value 2 of 4, in a range that runs from 0.47 to 2.2 uH.

    Where This Series Fits

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: mobile/smart phones; handheld/mobile equipment; tablets/e-readers; digital cameras; wearable devices.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.

    What is the difference between Irms and Isat?
    Irms is the DC current that produces the rated temperature rise. Isat is the peak current at which inductance has fallen by a defined percentage. A converter can run above Irms briefly but must stay inside Isat.