Eaton MPI2010V1-2R2-R 2.2 uH High-Current Inductor
Eaton MPI2010V1-2R2-R 2.2 uH High-Current Inductor

Eaton MPI2010V1-2R2-R 2.2 uH High-Current Inductor

Share
MPI2010V1-2R2-R: high-current power inductor, 2.2 uH, 2.2 A, Isat 2.6 A, DCR 117 mOhm.
    • Product Details
    • Download

    Eaton MPI2010V1-2R2-R 2.2 uH High-Current Inductor

    MPI2010V1-2R2-R at a glance: high-current power inductor, 2.2 uH, 2.2 A, Isat 2.6 A, DCR 117 mOhm.

    Key Specifications

    ParameterValue
    Orderable part numberMPI2010V1-2R2-R
    Inductance2.2 uH ±20%
    DCR maximum @ +25 °C117 mOhm
    Irms (DC, 40 °C rise)2.2 A
    Isat2.6 A
    SRF typical65 MHz
    K-factor1729
    MountingSurface mount
    Operating temperature-40 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, -R suffix
    Data sheetEaton Technical Data 10938

    Dimensions and Pad Layout

    MPI2010V1-2R2-R mechanical dimensions and pad layout

    Drawing reproduced from Eaton Technical Data 10938: outline with rated mm dimensions, pad layout and marking. Tolerances are stated on the drawing.

    Reading the Data Sheet

    Power inductors in this family are chosen on three numbers: inductance for the ripple, saturation current for the transient, and DCR for the loss. The data sheet gives all three against a defined test condition, which is what makes the row comparable with parts from other vendors.

    At 2.2 A the winding dissipates about 0.566 W in copper, using the 117 mOhm figure. That is the DC floor of the loss budget: ripple and core loss come on top of it.

    Saturation is reached at 2.6 A. Beyond that point the inductance falls on the soft part of the curve, and the converter’s ripple grows faster than the load current does.

    Within the MPI2010V1 family this is value 4 of 4, in a range that runs from 0.47 to 2.2 uH.

    Series Positioning

    The power inductor family covers sub-microhenry to tens of microhenry at currents from a few amps to tens of amps, in shielded surface-mount bodies. The data sheet rows carry both typical and maximum DCR so the loss budget can be built either way.

    • DCR is quoted at +20 °C. Copper resistance rises about 0.4 % per °C, so the hot loss is higher than the cold figure.
    • Typical applications: mobile/smart phones; handheld/mobile equipment; tablets/e-readers; digital cameras; wearable devices.
    • Design note: ripple from OCL, thermal from Irms, transient from Isat. Three different numbers, three different checks.

    Frequently Asked Questions

    Is the part shielded?
    The molded body encloses the winding, so the external field is small enough to place parts side by side on a multiphase rail.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Why are there two DCR columns?
    Typical and maximum. A guaranteed thermal design uses the maximum; a nominal efficiency calculation can use the typical.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products